Lowest Price Hm-III Medical Vital Signs Patient Monitor with Good Quality
You are here: Home » Products » Surgical&ICU Equipments » Patient Monitor » Lowest Price Hm-III Medical Vital Signs Patient Monitor with Good Quality

Category List

Lowest Price Hm-III Medical Vital Signs Patient Monitor with Good Quality

Availability:
Quantity:

PDF Export

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
  • Hm-III

Product Description

Four parameters: NIBP,SpO2,Pulse Rate,Temperature
* SpO2 waveform, PR strength display
* 2.8 inch color LCD with real time display
* Storage/Review trend data up to 3888 groups, data save time interval settable
* Audio and visual alarm when parameters exceeded and sensor-off
* Built-in rechargeable Li-ion battery, up to 4 hour running time
* Automatic shutdown for power saving, shutdown time interval settable
* Via USB to connect with the computer, unique software for telemonitoring
  by transmitting data synchronously via internet
* Battery capacity indicatior and prompt when battery low
 
Technical Specifications
 NIBP 
Measure Method: Automatic oscillometric
Patient: Adult and Pediatric
Measurement unite: mmHg/kPa selectable
Measurement mode: Manual, Auto, STAT
Measurement Type: SYS, DIA, MAP
Measurement interval in AUTO mode:1,2,3,5,10,15,20,30,45,60 and 90 Min
Measuring period in STAT mode: 5 Min
Measure range:
Adult:30~255 mmHg; child: 30~160 mmHg 
Accuracy: 1 mmHg
Alarm limits range:
SYS : Upper limits70~250 mmHg,     Lower limits 60~180 mmHg
DIA : Upper limits 40~200 mmHg,     Lower limits35~150 mmHg
MAP : Upper limits 60~230 mmHg,      Lower limits 50~160 mmHg
 SpO2 
Measure Range:  35~100%
SpO2 Accuracy:  2%(70~99%), 3%(40~70%)
Pulse Rate Range: 0~254 bpm
Pulse Rate Accuracy: 1 bpm
 Alarm limits range:
SpO2  upper limits : 95~100%   lower limits: 85~96%
Pulse Rate:keep up with the heart rate
 Temperature 
Channel: 1
Input: Body surface thermal-sensitive resistor temperature sensor
Measurement Unit: °C/°F selectable
Measure range: 0~50ºC
Alarm limits range: Upper limits 36~45ºC   Lower limits 34~38ºC
Measure accuracy: 0.1ºC
 System specifications 
Alarm ON/OFF: controlled by general switch and parameter switch (two levels)
Display mode: LED and 2.8' color LCD screen
Trend data: 3888 groups of SpO2, TEMP,SYS, DIA  trend data, The record time interval can be set to 5 Sec. to 120 Sec. , so that the record time rang can be  up to 128 hr.
AC power adaptor      
Input: AC 100~240V, 50/60Hz, 0.7A
Output: DC 5V,2.5A
Internal battery              
Type: 2800mAh/3.7V Li-ion rechargeable battery
Operating Time: 6 hours of stand-by time with a full battery.
Recharge time: 8 hours
Dimension:280mm*190mm*100mm 
Net Weight : 1000g
 

Standard Packing List
main unit1 piece
NIBP Extension Tube1 piece
Adult NIBP Cuff1 piece
Adult SpO2 Sensor1 piece
TEMP surface probe1 piece
AC power adapter1 piece
Communication cable1 piece
The operator's manual1 piece