Availability: | |
---|---|
Quantity: | |
PDF Export | |
HIP-820
Healicom
Product Description
Features:
1. 128*64 HD LCD Display, high capacity words, friendly user interface, dynamically display working status;
2. Female Voice alarm in English/Russian (other language is optional for customized machine)
3. Compatible with any brands of infusion sets after correct calibration;
4. Preset solution volume to greatly reduce the workload of nurses;
5. Work mode: ml/h and drop/min can switch freely;
6. Three levels of occlusion: high, middle and low;
7. Purge /Bolus function;
8. KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is 1ml/h---5ml/h (1ml/h step);
9. Power Source:100-240Vac, 50/60Hz;Internal rechargeable Li battery, capacity≥1,800mAh, voltage=11.1V, 4 hours backup time at the rate of 25ml/h (appointed medium rate in IEC60601-2-24) for the new battery charged for 12hours;
10. Automatically record the settings of last infusion;
11. It can store 2000pcs of infusion records and has drug library with 1000durgs.
Technical Specifications | |
Infusion Rate | ml/h mode: 0.1~1200ml/h (1ml/h step) |
drop/min mode: 1~266drop/min (1drop/min step) | |
Purge Rate | 100ml/h---1200ml/h (can be calibrated) |
Bolus | 800ml/h |
Flow Rate Accuracy | ml/h mode: Within ±5% (after correct calibration) |
drop/min mode: Within ±3% (after correct calibration) | |
Mechanical Precision | Within ±2% |
Maximum infusion pressure | 150kPa |
Volume Limit | 1---9999ml |
Total Infusion Volume | 0---9999.9ml |
Alarm Pressure | High 800mmHg±200mmHg (106.7kPa±26.7kPa) |
Medium 500mmHg±100mmHg (66.7kPa±13.3kPa) | |
Low 300mmHg±100mmHg (40.7kPa±13.3kPa) | |
Audible and Visible Alarms | There are bubbles,Tube is blocked,Close the door,IV set Mismatched,Battery running out,Infusion finish,Equipment failure, Abnormally Operation,Software Exception, Low battery,forget the operations etc |
Power Source | 100-240Vac, 50/60Hz; Internal rechargeable Li battery, capacity≥1,800mAh, voltage=11.1V, 4 hours backup time at the rate of 25ml/h (appointed medium rate in IEC60601-2-24) for the new battery charged for 12hours. |
Bubble Detector | Ultrasonic wave detector; detection sensitivity ≥25μL |
KVO Speed | 1---5ml/h (1ml/h step) |
Power Consumption | 40VA |
Fuse | T3.15AH/250V, 2pcs installed |
IP Classification | IPX2 |
Equipment Classification | Tubing Bubble, Infusion Completion, Flush Completed, Battery Under voltage, Equipment Failure (ER Series), Pause Timeout, Network Power On / Off, Feeding /watering Switching |
Noise | Internal rechargeable lithium battery 11.1V; battery life > 8 hoursafter and above. |
Power supply and input | 100-240V ~ 50 /60Hz ≤40VA |
Internal battery | Internal rechargeable lithium battery 11.1V; battery life > 8 hours |
Application field | internal medicine, surgical, pediatrics, obstetrics and gynecology, ICU, CCU, operation room and other clinical infusion treatment,etc.Also support the veterinary purpose |
Dimension | 140mm(L) x 157mm(W) x 220mm(H) |
Certificate | CE 0197, ISO13485, FSC |