HEA313 Medical Light Weight Electric Clinic Enteral Feeding Pump

Technical Specifications
Infusion rate (ml/h)
1~400 ml/hr in 1 ml increments
Mean flow velocity accuracy
±10% of selected flow rate
Dosage limit(ml)
0-9999 in 1 ml increment
Meanvolume accuracy
±10%
Loading speed andmeanaccuracy (ml/h)
1000±10%
Cleaning speed andmeanspeedaccuracy(ml/h)
1000±10%
Max volume flushandmeanspeed accuracy(ml)
40±10%
Mx feeding pump pressure
≥0.1 MPa
Occlusion alarm level (pressure)
50KPa±10KPa
The longest occlusion triggering time of this device at minimum flow rate
43min
The shortest occlusion triggering time of this device at intermediate flow rate
85s
Medium speed running the pills from blocking the alarm threshold
0.79ml
Recoverable Alarm
1min50s-2min
Pause overtime alarm time
1min50s-2min
Heating temperature
Infusion flow rate ≥20ml / h, 375px distance away from the heater outlet at 25-38 ºC
Use ofinfusionset
See recommended infusion sets list
Air-in-line sensitivity
Detestability of single size of air bubble ≥50uL
Alarm
Occlusion alarm, Over heatedalarm, battery depleted alarm
Alarms
Air in line,Prime, Flush, low power, failurecodes (ERxx), pause overtime, powerstate, infusion mode, work state, heaterstate.
Noise
Measured at the highest flow rate on wooden table, the volume is lower than 50 dB at a distance of 1 meter
Power
Ac: 100V-240V 50 Hz /60Hz
Built inbattery
A fully charged internal DC11.1V battery can continuously run the pump for approximately 5 hours on intermediate rate
Power consumption
≤40VA
Power output
≤20VA
The rated output voltage
15V
Weight
2.0kg
Heater
W-E01 ,cable length is 1.5m,Shield
Essential performance
This product is suitable for patients with enteral nutrition infusion, the host cancontrol the infusion rate. With alarmfunction,
with bubble detection piping and piping blockage detection.
Classification
type BF,class ΙΙ continuous volumetric feeding pump with internal battery; IPX1 (sealed drip-proof device)
Dimensions
155mm(L)×170mm(W)×180mm(H)
Accessories
1 user manual, 1 power cable, 1 heater (EA312/313 models only)