Product Description
Features
Classic peristaltic finger pump design, accept different brand and material international standard IV set, the deviation is within ±5% after calibration, Adjust level design to meet infusion needs in ICU, NICU, Pediatrics, Geriatrics, Oncology dept, etc. Double CPU to make infusion much safer and more effective.
Different adjustable level setting
Two occlusion pressure sensors, dynamic pressure value display, up-occlusion sensor to avoid underflow, 10 adjustable level for occlusion, air bubble and alarm volume to meet different needs in different department.
Long life battery backup
3000mAh Lithium battery, backup time more than 10hours under battery supply to ensure no interruption when no AC power supply or in moving condition.
Easy Operation
Big blue brightness LCD, number Keypad
Double CPU Design
Independent CPU design, reliable data transmission, safer infusion.
Various mode
ml/h, droop/min, volume/time, drug library, smart infusion
Real-time self-testing
Real-time self-testing during startup and infusing process, ensure the safety of each component and each function, safer infusion.
Technical Specifications | |
IV Sets | Standard single use IV sets(20 and 60d/ml, with diameter 3.4~4.5mm) |
Flow Rate Range | 1.0ml/h with 0.1ml/h; 100-1200ml/h with 1ml/h |
Flow Rate Increment | 1.0-100ml/h with 0.1ml/h; 100-1200ml/h with 1ml/h |
Flow Rate Deviation | <±5%(after calibration) |
VTBI | 0.1~9999ml |
Infused Volume | 0~999ml |
Time Setting | 1 min to 99h59min |
Purge Rate | 600ml/h, displaying purge volume |
KVO | 1ml/h~5ml/h, adjustable |
Keypad | Numeric Keypad, user friendly |
BOLUS Mode | Available for Bolus mode, flow rate adjustable |
Night Mode | Night mode, No operation for 5mins, LCD brightness lower automatically |
Occlusion Pressure Detection | Occlusion Pressure Sensor, detection range: 40-140Kpa, 10 levels adjustable, auto pressure release function |
Air-in-line Detection | Air bubble detected by ultrasonic with 10 setting, 50~300μL |
Alarm &Volume | 10 settings |
Anti-reverse Function | Anti-reverse function on motor to prevent upstream |
IV Set Management | Open System, Can accept all kinds of IV Set after calibration |
Self-Testing | Self-Testing when start up and during infusing |
Audio and Visual Alarms | Air-in-line, Door open, occlusion, parameter, IV Ste not calibrated, infusion finished, No operation, Leakage, battery low, Pump error. Motor reverse, AC power lost, etc. |
Display | 3.5" Brightness LCD |
AC power | AC:100V~240V, 50Hz/60Hz,≤25VA |
Battery | Rechargeable Lithium battery: DC11.1V, 3000mAh, life:≥10 hours remaining battery displayed |
Operation | Temperature: 5ºC~40ºC, Relative humidity:20%~90%, Atmospheric pressure:70~106Kpa |
Transportation and Storage | Temperature: 20ºC~55ºC, Relative humidity:10%~90%, Atmospheric pressure:70~106Kpa |
Classification | Class I, CF, IP*3 |
Dimension | 150mm*10mm*210mm |