HEA323 Medical Portable Double Nutrition Feeding Pump

Technical specifications
Infusion preset range (ml)
Feeding volume: 0-9999, adjusted by 1
Water feeding volume: 0-999, adjusted by 1
Infusion(feeding or watering) accuracy
±10% or±0.2ml/h(choose the larger value)
Feeding speed setting range (ml/h)
1~800, adjusted by 1
Feeding speed accuracy
±10% or±0.2ml/h(choose the larger value)
Water feeding speed and accuracy (ml/h)
1000±10%
Flushing speed and accuracy (ml/h)
1000±10%
Single Flushing dose (ml)
25±10%
Perfusion speed and precision (ml/h)
1000±10%
Perfusion dose (ml)
10ml±10% nutrition and 25ml±10% water
The Maximum infusion pressure
≤0.1 MPa
The trigger alarm time at minimum flow rate
42min18s
The trigger alarm time at medium flow rate
1min30s
The amount of bolus produced by Medium speed up to the blocking alarm threshold
0.49ml
Blocking alarm threshold (pressure)
50KPa±10KPa
The recoverable time when alarm is automatically restored after the time is out
1min50s - 2min
Pause time when alarm timeout
1min50s - 2min
The heating temperature
When the feeding speed is greater than 20ml/h,15cm distance heater outlet is 25-38ºC
Bubble sensitivity
A bubble that can detect a single volume greater than 50uL
Intestinal feeder
Special intestinal feeding device
Alarm function
Tube occlusion, battery exhaustion, overtemperature
Prompt function
Tubing Bubble, Infusion Completion, Flush Completed, Battery Under voltage, Equipment Failure (ER Series), Pause Timeout, Network
Power On / Off, Feeding /watering Switching
Noise
When operating at the maximum flow rate on the wooden desktop, noise level are below 50dB in the distance of 1 meter at the front, after and above.
Power supply and input
100-240V ~ 50 /60Hz ≤40VA
Internal battery
Internal rechargeable lithium battery 11.1V;
battery life > 8 hours
Output
≤20VA
Rated output voltage
DC15V
Total Weight
About 1.5kg
Rate
Class II BF type continuous operation capacity type nutrition pump with internal power supply;
Class IPX1 (anti-dripping device)
Dimensions
135mm (L) ×105mm (W) ×160m (mH)
Accessory
1 User's Manual and other document, 1 adapter, 1 set of intestinal feeding device and heater


Previous: 
Next: 
HEALICOM MEDICAL EQUIPMENT CO.,LTD 

Healicom Medical Equipment Co.,Limited

Healicom Medical Equipment Co.Limited. is a leading professional supplier with Medical equipments in China.

Quick Link

Solution

Contact Us
Leave Message
Copyrights ©2021 Healicom Medical Equipment Co., Ltd. All Rights Reserved. Technology by leadong | Sitemap