Portable digital ECG system for clinics, featuring automatic interpretation, multi-lead acquisition, real-time waveform display, rechargeable battery, and compact design. Ideal for efficient cardiac screening and reliable electrocardiographic assessment.
Availability:
Quantity:

PDF Export

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
  • HE-3D

  • Healicom

Product Description

HE-3D

ECG system

3.png

Main Unit

Lead

Lead acquisition

Sampling rate

Working mode

Filter

CMRR

Input circuit

Input impedance

Patient current leakage

Frequency response

Calibrating voltage

Sensitivity

Paper feeding speed

Accuracy of data

Time constant

AD conversion

Inter-channel interference

Noise level

HR detection range

Standard 12 leads ( I, II, III, aVR, aVL, aVF, V1 to V6 )

12 leads synchronously acquisition

32000Hz

MAN, AUTO, R-R, STOR

AC Filter: 50Hz / 60Hz / Off

EMG Filter: 25Hz / 45Hz / Off

≥120dB (with AC Filter)

Floating; Protection against defibrillator effect

≥2.5MΩ (10Hz)   

<10μA

0.05-150Hz (-3dB)

1mV±5%

2.5, 5, 10, 20, 40, mm/mV (±3%), Auto

6.25, 12.5, 25, 50mm/s(±3%)

<±5% or <±40μV

≥3.2s

12 bits

<2%

<30μ Vp-p

30-300 BPM (±1BPM)

Pacing Pulse

Identification

Amplitude

Width

Sampling rate

2mV-250mV

0.1ms-2.0ms

4000Hz/Channel

Recorder

Recording way

Recording format

Paper specification

Thermal dot matrix recording

1chx12+R, 3chx4, 3chx4+R, 1 minute rhythm lead record

80mmx20m, roll paper

Others

LCD display

Patient cases storage

Communication interface

AC power supply

DC power supply

Fuse specification

Measurement and weight

800x480 graphic 7 inch color couch LCD  

400 patient cases ( Internal SD card is optional )

USB, UART

110-230V (±10%), 50/60Hz (±1Hz), power 60VA

Rated voltage/capacity: 7.4V, 2200mAh, Lithium battery

Rated charging current: 1300mA

Rated charging cycle number: not less than 500 times  

TZAH/250W, ф5X20

265mm×228mm×68mm,1.6kgs

Environment

Working Environment

Storage Environment

Ambient temperature: +5°C~+40°C

Relative humidity: 25% to 80% (no condensation)

Atmospheric pressure: 700hPa ~ 1060hPa

Ambient temperature: -20°C ~ +55°C

Relative humidity: 25% to 93%

Atmospheric pressure: 700kPa~1060kPa

7.png
8.png

Optional Functions

●  Use the PC ECG Management Software to manage ECG date on computer ( acquisition of real-time ECG,

edit, import, save, print and transfer ECG report, VCG examination and etc. ).

●  Transfer ECG data to USB disk for storage, then upload data to computer for management.

●  Connect to a bar-code scanner to scan patient ID.