Availability: | |
---|---|
Quantity: | |
PDF Export | |
HCX-70B
Healicom
Product Description
· Advanced functions of lmages optimization, strengthen module,real-time displaying the clear clinical images.
· Professional working station has more image post-processingfunctions such as the image W/L adjustment, region of interest balance.GAMMA correction,flip, noise reduction, smoothing,sharpening etc.
· Two monochrome 19" flat-screen monitors clearly visualize thesmallest anatomical details.
· Short, sharp pulses for clear images and the radiation exposure for the operators and patients can be reduced to a minimum.
· Motorized iris collimator with multi-leaf, supports high accuracy for selected x-ray field size.
· Crosshair overlay corresponding with laser light, designed for easily checkpoint location before operation, avoiding unnecessary exposure.
· Professional remote controller for exposure, allows operators retreating to X-ray exposure.
· Professional storage system for single and continuous images, reducing the repeatability of the exposure.
· Hand controller on C-arm stand: control the mechanical and collimator movement, improve your workflow even you are away from the unit.
· Hand controller on the workstation trolley: select the mode offluoroscopy.
· Synchronized dual touch-screen panels mounted on C-arm stand, with intuitive user interface and APR parameters setting, make the exposure control at your hand all the time.
· Double rotatable flat-screen monitors on the trolley, clearly visualizethe smallest anatomical details even at an angle.
· The wide opening and depth ofthe arc make for precise alignment withminimum interference with the operating area.
Technical parameters | HCX-70B |
High Frequency Inverter power supply | output power: 12kw |
Inverter frequency: 60KHz | |
Automatic , Manual continuous Fluoroscopy | Tube voltage:40kv~ 125kv continuous adjustment |
Tube current:0 . 3mA 4mA Continuous adjustment | |
Automatic , Manual Intensifying Fluoroscopy | Tube voltage:40kv~ 125kv continuous adjustment |
Tube current:0 . 3mA~ 8mA Continuous adjustment | |
Automatic , Manual Pulse Fluoroscopy | Tube voltage:40kv~ 125kv continuous adjustment |
Tube current:0 . 3mA 30mA Continuous adjustment | |
pulse frequency:0 . 1 - 10 frame/s continuous adjustment | |
DS Digital spot Film | 0 . 1 - 10 frame/s can be chosen freely |
Radiography Tube voltage, mA | 40kv ~ 125kv 1 60mA |
X-ray Tube special For High Frequency | Rotary anode focus: 0 . 3/0 . 6 |
Anode thermal capacity: 212KJ |