| Availability: | |
|---|---|
| Quantity: | |
| PDF Export | |
FCA800
Healicom
Product Description
Feature:
● High throughput random acess...
● 800 tests/hr or 960 tests/hr (with ISE mould).
● New style software, more friendly, efficient and convenient.
● Water-bath incubation technology ensures accurate reaction temperature.
● Frequency conversion technology makes movement more stable,reliable and lower noise.
● Perfect self-test and position auto-locating function minimize mechanical error.
● Auto stand-by function for saving energy consuming and 24 hours ready for work.
● Perfect Instrument-Reagent-Control/Calibrator system ensures the results with good traceability and coherence.

| Product Paramenters | ||
| Model | FCA800 | FCA600 |
| Assay types | Random access | |
| Throughput | 960 Thr(include ISE), 800 T/Hr(biochemical test only) | 760 Thr(include ISE), 600 THr(biochemical test only) |
| Analytical methods | End point, Kinetic(Rate), Fixed time, Single standard, Multi-standard, Single wavelength assay, Bichromatic, Bi-reagent assay, Serum blank assay, Immunoturbidimetric assay and ISE assay (KNa\Ca\CAPH) | |
| Sample capacity | 2 x 92 primary tube or micro serum cup | 1 x 92 primary tube or micro serum cup |
| Sample/reagent probe | With liquid level sensor, automatically checking and tracking reagent allowance ability, internal and external nano treated, stereoscopic collision protection, plugging probe checking ability | |
| Sample volume | 1.0- 100ul in 0.1 ul/step | |
| Reagent volume | 1-500ul in 0.1 ul/step | |
| Reagent tray | 2 reagent trayes, barcode scaner available (on request), R3/R4 assay models available | |
| Reagent refrigerater | 2-8℃, 24 hrs available | |
| Reading Cuvette | 160 cuvettes, made of ultraviolet transmitable plastic(or quartz glass cuvettes available on request) | |
| Reaction volume | Minimum 120 μl | |
| Reaction disc temp. | Water bath system, 37土0.1"C,(air bath on request) | |
| Cuvette cleaning | Automatical warm water washing station with 8 channels, blank reading for ensuring each cuvette well cleaned before using. Smart detergent clean for high contamination cuvette and probe, efficiently decreasing carry-over | |
| Carry-over | Less than 0.05% | |
| Monochromator | Concave grating | |
| Wavelength range | 340-810nm | |
| Alarm | Automatic alarm for lack of reagent, sample,water, or waste filled and other errors, showing the info on monitor | |
| Mixer | 2 nano-surface treated mixing probers, with automatic warm water washing station for each one | |
| Quality control | Multi-level QC for the same item automatically monitoring and alarming if the results out of control | |
| Assay Linearity range | Wide linearity range measuring, also with automatically diluting function for high value sample | |
| Calibration | Single or multi-points calibration, supporting linear and nonlinear assay | |
| Data processing | Powerful software for calculating, blanking, multi-analysis, data reviewing, QC and results management, on line monitoring, editing etc. | |
| Data storage | Long-term storage, storage capacity upon PC hard disc | |
| Print | Multi report formats and user-self- defined report format are available | |
| Power supply | AC 110V/60Hz or 220V/50Hz | |
| Dimensions | 1200mm x 900mm x 1100mm | |