FCA161 Laboratory Fully Automated Clinical Chemistry Analyzer

Feature:

1. No touch mixing function, greatly reducing water consumption and decreasing carry-over.

2. Lower reagent consumption technology, greatly saving reagent's production, transportation and storage cost, and decreasing carry-over (On request, down to 80ul/test)

3. New cooling system, steadily keeping reagent chamber in 2-8℃.

4. Auto perameter setting function.


Technical specifications
Operation
Random access
Reading System
Direct reading system
Method
End point, Kinetic, Fixed time, Bi-chromatic, Immunoturbidimetric,
1-2 reagent multistandard, reagent/serum blank, etc
Assay Item
36 assay items
Throughput
1 Reagent: 200 tests/h (max)
2 Reagent: 150 tests/h (max)
With ISE: +100 tests/h
Sample Position
50 postions
including standard, control stat; either serum cup or primary tube available
Sample Volume
1-100µL, 0.1µL/step
Reagent Position
36 positions
Reagent Volume
1µL-500µL, 0.1µL/step
Reagent/Sample Probe
With liquid level sensor, collision sensor
Reaction Time
0-999seconds
Cuvette
High quality UV-transmitted plastic cuvette, or quartz glass cuvette on request
Cuvette Time
5 channels automatic washing system for reaction cuvettes
Independent washing station for each sample/reagent probe and mixer
Alarm
Automatic alarm for malfuction (e.g: collision, reagent and distilled water insufficiency, waste container ful, etc)
Calibration
Linear, Non-linear, Multi point, K factor
Sample Dilution/Retest
Sample can be diluted and retested if results are out of range or sample is insufficient
Wavelength
340-810nm
Light Source
Halogen lamp
Absorbance Resolution
0.0001A
Absorbance Accuracy
±0.0003A(0~2.5A)
Repeatablility (CV%)
ALT<3%, UREA<2.5%, TP<1.5%
Quality Control
Levy jennings quality control program at 3 levels
Bar Code
Optional
Printer
Multiple report formats available
Other
Tele-diagnostic, bi-direction interface to LIS syste, etc
Language
English, French, Spanish, German, Russian, etc
System
Windows XP or Vista
Power Supply
220V/50Hz, or 110V/60Hz
Dimension
65 x 53 x 52cm
Weight
50Kg