  • HT-4000

  • Healicom

Product Description

HT-4000 Transport Emergency Infant Incubator

Product Feature
1. Two temperature control modes: Air mode and Baby mode controlled by micro-computer
2. Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance
3. Set temperature, air temperature, baby temperature and internal battery voltage can be displayed separately
4. Failure alarm indication
5. Can be equipped with > 37°C temperature set function
6. Double wall Acrylic glass hood with side door so that the bassinet can be pulled out from it
7. Natural air flow humidity
8. The height of whole unit can be adjusted
9. Oxygen supply system
10. Observation lamp
Standard Configuration
1. Main body (Include the hood, controller, bassinet, internal battery, and observation lamp)
2. Oxygen supply system
3. Skin temperature sensor
4. I.V. Pole
5. Mattress
6. Adjustable stand

Optional Configuration
">37ºC" override temperature mode, disposable skin temperature sensor, ambulance trolley.

Techincal Specifications
AC Power requirement
AC220V-230V/50Hz, or AC110-120V/50-60Hz, 400VA
DC Power requiremet
DC12V/10A or DC2V/6A
Control mode
Air mode and Baby mode controlled by micro-computer
Air temperature control range
25°C-37°C (Override mode 37°C-38°C)
Baby temperature control range
34°C-37°C (Override mode 37°C-37.5°C)
Skin temperature sensor accuracy
±0.2°C
The temperature flucuation range bwtween incubator temperature and average incubator temperature (under stable temperature
condition)
≤1.0°C
Temperature uniformity
≤1.5°C (mattres is on the horizontal position)
Noise inside hood
≤52dB(A)
Failure alarm
over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm and so on.
Battery continuous working time
90 min (set temperature is 36°C-Ambient temperature is 15°C)


Main components of the incubator

Previous: 
Next: 
HEALICOM MEDICAL EQUIPMENT CO.,LTD 

Healicom Medical Equipment Co.,Limited

Healicom Medical Equipment Co.Limited. is a leading professional supplier with Medical equipments in China.

Quick Link

Solution

Contact Us
Leave Message
Copyrights ©2025 Healicom Medical Equipment Co., Ltd. All Rights Reserved. Technology by leadong | Sitemap