Availability: | |
---|---|
Quantity: | |
PDF Export | |
HC01
Healicom
Product Description
Mainly used for patients with mild to moderate respiratory failure, no indication of emergency intubation, relatively stable vital signs and no taboo of noninvasive ventilation. It is used for early intervention and auxiliary evacuation of respiratory failure.
Nowadays,COVID-19 which causedby the novel coronavirus outbreaks worldwide.The virus will quickly invadehuman lung cells and cause pneumonia, which will cause severe lower respiratory tract diseases, such as acute lung injuryand respiratory distress syndrome. Some critical pati-entmay even have symptoms such as respiratory failure, refractory hypoxemia,shock,mul-tiple organ failure,and coagulopathy. For COVID-19,ventilator is one of the most effective treatments in the absence of specific drugs.Under ventilated, the blood oxygen of patient can be effectively improved and the mortality rate can be reduced.
HC01 can be used in para treatment for patients with COVID-19
1. Small size, color LCD display
2. Portable and easy to operate
3. Can be equipped with trolleys
4. Can be Equipped with multi-stage
5. humidification function;
6. Real-time display and monitoring of clinical
use data of patients;
7. Connect to Low-flow oxygen, for air-oxygen mixing;
8. Max.IPAP: 25cmH2O;
9. Ventilation mode: CPAP, S, S/T, T .
Non-invasive ventilation is mainly applicable to patients with mild to moderate respiratory failure, no evidence of emergency intubation, relatively stable vital signs, and no contraindications to non-invasive ventilation. It is used for early intervention and assisted withdrawal of respiratory failure.
Using environments
1. Early intervention for respiratory failure for patients with COVID-19;
2. After extubating, when the patient is removed from the invasive ventilator and transferred to a
non-invasive ventilator.The patient has a certain ability to breathe spontaneously and is in good
condition, or applied when transferred to a general ward.
Guidelines for non-invasive ventilation for patients with COVID-19
For mild to moderate patients (PaO2<60mmHg,SpO2<90%,RR>24), non-invasive ventilation
can be considered for respiratory support when oxygen therapy is not effective.
Qualification
ISO 13485, CE0197, ISO14001, ISO 9001
Product name | Non-invasive ventilator |
Model | HC01 |
Screen | 3.5'' colorful LCD |
Respiratory mode | CPAP、S、S/T、T |
Weight | 1.8Kg |
Dimension | 255mm*170mm*112mm |
Noise Level | <30dBA |
Parameters | IPAP(cmH2O):4-25cmH2O EPAP(cmH2O):4-25cmH2O |
Isens | 1-6 level |
Esens | 1-6 level |
Islop | 1-6 level |
InspTime | 0.5-3s |
BPM | 4-40bpm |
Humidifier | 0-5 level |
Auto-On/Off | On/Off |
Auto-air compensation | Available |
Auto-air compensation | Available |
Ramp | 0-60 min |
Detail Image