Linegene 9600 Plus
Healicom
Product Description
Feature:
• Line-Gene 9600 Plus adopts Ferrotec specially-made Peltier, advanced fiber optic technology, new global wide-range power supply, the unique patented block dissipation technology and bottom detection mode, which provides better heating/cooling rate, temperature accuracy, uniformity and stability.
• Line-Gene 9600 Plus has up to 96 sample capacity and fast speed of dual-color scanning, and the design of 5 channel detection also covers the whole fluorescence detection wavelength.
• Newly-designed automatic hot-lid without manual operation ensures constant pressure for various tube heights.
• This auto hot-lid mode could be easily integrated into various automatic systems. Its Windows tablet computer and new touch screen brings excellent operating experience.
• Newly-improved Line-Gene 9600 Plus Real-Time PCR detection system can satisfy various clients' requirement either for research or clinical use.
Technical Specifications | |
Product name | LineGene 9600 Plus Fluorescent Quantitative Detection System |
Sample Capacity | 96x0.2ml PCR plate, 12x 8-strip tubes, 96 x0.2ml single tube (transparent bottom) |
Reaction system | 5~100ul |
Dynamic range | 1-1010 Copies |
Detected Fluorescence | F1: FAM, SYBR Green I F2: VIC, HEX, TET, JOE, CY3, NED, TAMRA F3: ROX, TEXAS-RED F4: CY5 F5: CY5.5 |
Excitation wavelength | 300-800nm |
Detection wavelength | 500-800nm |
Module working temperature range | 4-105℃ (resolution: 0.14℃) with SOAK low temperature storage function |
Temperature control precision | ±0.1℃ |
Temperature uniformity | <±0.3℃ |
Hot lid temperature range | 30-110℃ (adjustable, default by 105℃ and automatic hot lid) |
Temperature control mode | Block Mode and Tube Mode (automatic control based on liquid level) |
Operation mode | Continuous operation |
Gradient temperature range | 1~36℃ |
Fluorescence intense detection repetition | 5% |
Scanning mode | Full-plate scanning and designated line scanning |
Scanning time | 5.5s |
Special function | Absolute quantitative automatic analysis, relative quantitative, 5NP analysis, melting Curve analysis, 6 independent temperature 7ones, HRM, Multi-channel| crosstalk calibration, background correction, auto gain, customizable parameters, etc. |
Programming | Max.20 segments for each program, max.99 cycles |
Operating system | Microsoft: Windows 7/Windows 8.1/Windows 10 |
application software: Excel 200:2002/2003/2007/2012 | |
Minimum computer configuration | RAM: 512M. hardware space: 10GB CPU: Pentium 4 virtual memory: ≥1000MB |
Port method | Support USB and R5232 data port and Bluetooth port |
Input power | 100-240v, 50/60Hz. 600W |
Outer dimension | 410mmX386mmX352mm |
Certification | Ferratec Peltier/CE/EMC/RoHS2.0/PICC Product Quality Liability Insurance/VD/MET |