Best Price Veterinary Medical Equipment WTK-100 VET Veterinary Animal Infusion Pump
Feature |
· History records · Mini-size, light weight, easy operation · KVO function, KVO starts automatically when infusion is finished · Anti-reverse rotation detection · Various visual and audible alarms · Real time display · 3 adjustable occlusion pressure settings · Removable pump body, convenient for cleaning · Free- flow protection · Double CPU ensuring safe infusion |
Specification |
Infusion rate | 0.1-1200ml/h |
Infusion accuracy | ±5% |
Applicable infusion set | Various brands of standard infusion set |
Volume to be infused (VTBI) | 0-9999ml |
Volume infused | 0-36000ml |
KVO rate | 1-5ml/h |
Bolus rate | 300-1200ml/h |
Infusion mode | Rate mode, Drip mode, Time mode, Body weight mode |
Purge rate | 600ml/h |
Air bubble detection | Ultrasound sensor detection with four levels of air in line alarm |
Occlusion pressure | (400-160.0)Kpa 3 adjustable occlusion pressure: low-middle(default)-high |
Function | Removable pump body for easy cleaning |
KVO | |
Adjustable buzzer volume | |
Anti-bolus(diminishes the unwanted volume of Bolus injected to the patient after removal of occlusion) | |
Ultrasound sensor detection with four levels of air in line alarm adjustable | |
Intelligent pressure detection alarm | |
Anti-reverse detection | |
History records and can be looked up through computer | |
Screen simultaneously display the infusion rate, drip rate, VTBI, Volume infused, real time etc. | |
Bolus | |
Alarm | Use battery, Door open, Occlusion, Almost done, Forget operate, Infusion completion Battery exhausted, malfunction etc. |
Power supply | DC:12±1.2VAC:100-240V,50/60HZ |
Power consumption | 25VA |
Nurse call interface | Optional |
Wireless monitoring system | Optional |
Classification | Class I, type CF |
Dimension | 145*100*120mm( L*W*H) |
Weight | 1.4KG |
Waterproof level | IPX3 |
Occlusion pressure | (400-160. 0)KPa 3 adjustable occlusion pressure: low, middle, high |
Battery | Rechargeable Li_Polymer battery, 7.4V 1900mAh |
Battery charging time | 10 hours with power on, 3 hours with power off |
Battery operating time | About 6 hours at 25ml/h |
Operating conditions | Temperature: 5℃-40℃, Relative humidity:10-95 %, Atmosphere pressure: 86-106kPa |
Transport conditions | Temperature: -20℃-60℃, Relative humidity:10-95 %, Atmosphere pressure: 50-106kPa |
Storage conditions | Temperature: -20℃-45℃, Relative humidity:10-95 %, Atmosphere pressure: 50-106kPa |