HIMS972 High Accurate Portable Automatic Electrolyte Analyzer

Feature:

• Simple YES/NO prompted operation

• High accurate and long life electrode and TCO2 sensor

• Sleep mode to reduce reagent consumption

• Rapid test speed of 80 tests per hour

• Minimum sample volume is 60ul

• Individual reagent to avoid waste

• Option:Sample tray


Parameter configurations

1. K, Na, Cl

2. K, Na, Cl, TCO2

3. K, Na, Cl, iCa, nCa, TCa, pH

4. K, Na, Cl,iCa, nCa, TCa, pH, TCO2, AG

5. K, Na, Cl, Li

6. K, Na, Cl, iCa, nCa, TCa, pH, Li

7. K, Na, Cl,iCa, nCa, TCa, pH, Li, TCO2, AG

8. K, Na, Cl,iCa, nCa, TCa, pH,Mg, TCO2, AG

9. K, Na, Cl,iCa, nCa, TCa, pH, Li, Mg, TCO2, AG


Main Features

• Automatic electric potential tracking and correcting software to ensure the stable performance.

• Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement.

• Real-time diagnostic of system working status.Waste liquid automatic detection and alarming.

• Automatic calibration and two-point correction to adjust slope and intercept.

•Wave theory flushing method and direct flushing pipe method to avoid block and crossed contamination. • Power failure protection to avoid data losing, data storage could be extended to more than 20,000.

• Available to power off any time, therefore reduce reagent consumption, suitable for any hospitals.


Technical Specifications
Sample
serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring speed
≤25s
Analysis Method
ion selective electrode (ISE)
Sample volume
60-300ul (3 parameters to 11 parameters)
Sample position
35 positions (including 1 QC)
Storage
up to 10,000 test results
Printer
Internal thermal printer
Interface
RS232 port
Working environment
Temperature: 5-40℃Relative Humidity: ≤ 80 %

Atmospheric pressure: (86~106) kPa
Power supply
220V±20V, 50-60Hz
Power
≤120W
Dimension
380mm*270mm*400mm
Net weight
8Kg