HP-810 Medical Table Top Oximeter with NIBP
You are here: Home » Products » HP-810 Medical Table Top Oximeter with NIBP

Category List

loading

HP-810 Medical Table Top Oximeter with NIBP

Quantity:

PDF Export

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
  • HP-810

  • Patient/Fetal/Maternal Monitor

  • All

  • Ssyjxzz20122210576

  • SpO2 Waveform

  • ±1bpm or ±1%(The Larger One)

  • Below 30mA

  • -10°c-40°c

  • ±1%

  • Carton

  • Jiangsu, China

  • Physiological Functions of Diagnosis and Monitoring Equipment

  • CE, ISO13485

  • Type 2

  • Three Parameters: SpO2, Pulse Rate, NIBP

  • 30bpm-240bpm

  • Two AAA 1.5V Alkaline Batteries

  • 5°c-40°c,

  • 70kpa-106kpa

  • Healicom

  • CE, ISO

  • 9018909090

Product Description

Parameters
Three Parameters: SPO2, Pulse Rate, NIBP
 
Waveforms
SpO2 Waveform
 
Features
COLOR OLED display, four direction adjustable.
SpO2 and pulse monitoring, and Waveform display.
Low-power consumption, continuously work for 50 hours.
Small in size, light in weight, and convenient to carry.
Low voltage alarm display, Auto power-off.
Runs on standard AAA batteries.
 
Detailed descriptions of product functions:
SPO2
Measurement range: 70%-99%
Accuracy: ±2% on the stage of 70%-99%, unspecified(<70%) for SPO2
Resolution: ±1%
Low perfusion: <0.4%
PR
Measurement: range:30BPM-240BPM
Accuracy: ±1BPM or ±1%(the larger one)
Power: two AAA 1.5V alkaline batteries
Power consumption: below 30mA
Automatic power-off: the product shuts down automatically after no signal for 8 seconds
Dimension: 62mm×32mm×33mm
Operation environment:
  Operation temperature: 5°C-40°C,
  Storage temperature: -10°C-40°C
  Ambient humidity: 15%-80% on operation,
                  10%-80% in storage
  Air pressure: 70kPa-106kPa
NIBP monitoring
Measurement method: Oscillometry
Measurement mode: manual/auto/continuous.
Auto measurement interval: adjustable from 1 to 255 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
Self-check function.
Overpressure protection: double protection for software and hardware.
Range: Adult:
 Systolic pressure: 40mmHg~270mmHg
 Mean pressure: 20mmHg~235mmHg
 Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
 Systolic pressure: 40mmHg~200mmHg
 Mean pressure: 20mmHg~165mmHg
 Diastolic Pressure: 10mmHg~150mmHg
Neonate:
 Systolic pressure: 40mmHg~135mmHg
 Mean pressure: 20mmHg~110mmHg
 Diastolic Pressure: 10mmHg~100mmHg
 Upper and lower limit of alarm

 
Neonate  
Systolic pressure 40mmHg~135mmHg
Mean pressure 20mmHg~110mmHg
Diastolic Pressure 10mmHg~100mmHg

HP-810 Medical Table Top Oximeter with NIBP
 
HP-810 Medical Table Top Oximeter with NIBP
HP-810 Medical Table Top Oximeter with NIBP
Previous: 
Next: 
HEALICOM MEDICAL EQUIPMENT CO.,LTD 

Healicom Medical Equipment Co.,Limited

Healicom Medical Equipment Co.Limited. is a leading professional supplier with Medical equipments in China.

Quick Link

Solution

Contact Us
Leave Message
Copyrights ©2025 Healicom Medical Equipment Co., Ltd. All Rights Reserved. Technology by leadong | Sitemap