Surgical Equipment HA-12Apro Trolley Anesthesia Machine
Performance characteristics
- Adopt electronic control and pneumatic control methods.
- Has a variety of alarm, prompt and protection functions.
- Controlled by touch and button
- parameters, alarm information, waveforms and ring diagrams
- It has a power outage support function. When the mains power is cut off, it will automatically switch to the internal backup power supply.
- HA-12APro use 12.1 -inch high-definition color LCD to display ventilation Display background switching function (day/night.)
- Suitable for both adults and children.
- With capacity control, pressure limit and other working methods.
- Adopt temperature, flow and pressure compensation, Anesthetic evaporator with automatic altitude compensation function and zero-position self-locking.
- Built-in electronic flowmeter
- Linkage device to ensure that the O2 concentration is ≥25%.
- With O2 driving pressure insufficient alarm and N2O cut-off protection.
- Carbon dioxide monitoring module.
- Optional exhaust gas transmission and collection system.
- Optional anesthetic gas monitoring module.
Ventilator parameter range | |
Flowmeter | O2, N2O, AIR (0 ~ 10 L/min) |
Rapid oxygen supply | 25 L/min ~ 75 L/min |
Tidal volume(Vt) | 20 mL ~ 1500 mL |
Adult: 300 mL ~ 1500 mL | |
Children: 20 mL ~ 300 mL | |
I:E | 4:1 ~ 1:8 |
PEEP | OFF, 3 cmH2O ~ 30 cmH2O |
Pressure triggering sensitivity (PTr) | -20 cmH2O ~ -1 cmH2O |
Flow trigger sensitivity (FTr) | OFF, 0.5 L/min ~ 30 L/min |
Pressure control (PC) | 5 cmH2O ~ 70 cmH2O |
SIGH | OFF, 1/100 ~ 5/100 |
Suffocation time | OFF, 5 s ~ 60 s |
Respiratory rate | 1/min ~ 100/min SIMV: 1/min ~ 40/min |
Adult: 4/min ~ 40/min | |
Children: 10/min ~ 100/min | |
Inspiratory time | SIMV: 0.2 s ~ 10.0 s Adult: 0.3s ~ 10.0 s |
Children: 0.2 s ~ 4.8 s | |
Support pressure | 5cmH2O ~ 70cmH2O |
Rapid oxygen supply flow | 25L/min ~ 75L/min |
Fresh gas outlet pressure | 30 kPa ~ 45 kPa |
Ventilation mode | |
IPPV, A/C (V-A/C, P-A/C), SIMV (V-SIMV, P-SIMV) | |
PCV, PCV-PC, PCV-VG, PSV, MANUAL |
Company Profile
FAQ
1. What about the price level?
We are confident that our prices are competitive compared with those at the same quality level, since we have stayed in this filed more than 20 years. And we always adhere to the principle of provide top quality products with competitive prices. We have already established our good fame in many countries, especially in Africa, Middle East, European, Asia and South American through year after year efforts.
2. Why we find some prices are very high compared with some other supplier, and from the picture or it's model number, all looks the same?
As China is still a developing country, there are only a few products with patent rights, and copy products I spread very fast in the market. Of course, the prices of those copy products with cheap material and less quality control are relatively cheaper.
3. What is time of delivery?
Since our products are produced according to each specific order, the delivery period will be 15 days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible.
4. What about quality assurance?
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge.
5. What is payment terms?
T/T, Credit Card, L/C, Western Union, PayPal, MoneyGram.