HC-7000D Portable Biphasic AED External Defibrillator Monitor
You are here: Home » Products » Surgical&ICU Equipments » Defibrillator » HC-7000D Portable Biphasic AED External Defibrillator Monitor

Category List

HC-7000D Portable Biphasic AED External Defibrillator Monitor

Availability:
Quantity:

PDF Export

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
  • HC-7000D

  • Healicom

Product Description

HC-7000D Portable Biphasic AED External Defibrillator Monitor

AED Model

AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts 

Shockable Rhythms: Ventricular fibrillation, Ventricular tachycardia, QRS complex wave duration 

Charge Control: Control on device front panel, press key on paddle


Manual Mode

Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70,100, 150, 200, 300, 360 joules 

Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor

IMG_1144

Technical Specifications
Display
Screen Type
High-resolution display
Screen Size
7 inches(17.7 cm) diagonally
Sweep Speed
25mm/sec
Information
Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy
Defibrillator
Waveform
Biphasic
Energy Display
Monitor display indicates both selected and delivered energy
Charge Prompt Type
Voice and visual prompts
Electrode Impedance Measurement Range
0-250 ohms
ECG Monitoring
Patient Connection
3-1ead ECG cable, or 5-1ead ECG cable, paddles
Lead Selection
Displayed on monitor, paddles, l, Il, IAVR, AVC, AVF, V
ECG Size
0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate
20-300BPM
Heart Rate Alarm
On/Off displayed on monitor, user-selectable
Smart Alarms
Beeper/voice prompts indicate shockable rhythm
SpO2 Module
Measurment Range
30-100%, ± 2% between 80%-90%, others ± 5% :
Alarm Range
User set high limit and low limit
Alarm Accuracy
± 10% within setting values
Alarm time Accuracy
less than 12 sec
Recorder
Paper
50mm thermal
Speed
12.5mm/sec, 25mm/sec, 50mm/sec.User-selectable 6-second delay
Printing Method
High-resolution, thermal array print head
Print-out Modes
Manual or automatic, user-configurable
On/Off Control
Front panel and paddle
Automatic Function
9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge
Battery
Type
Rechargeable, Ni-MH battery, 12V
Operating Time
For a new, fully charged battery60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG
monitoring.Additional parameters will effect operating time with different functions.

IMG_1146

Previous: 
Next: 
HEALICOM MEDICAL EQUIPMENT CO.,LTD 

Healicom Medical Equipment Co.,Limited

Healicom Medical Equipment Co.Limited. is a leading professional supplier with Medical equipments in China.

Quick Link

Solution

Contact Us
Leave Message
Copyrights ©2021 Healicom Medical Equipment Co., Ltd. All Rights Reserved. Technology by leadong | Sitemap